Signal Integrity Data
I-PEX offers simulated S-parametric data for CABLINE® Series connectors using coaxial cables in both Single Ended, 45 Ohms reference impedance and Differential 85 Ohms reference impedance configurations. The Signal Integrity test report includes the Insertion Loss, Return Loss, Near End and Far End Cross Talk data up to maximum operating frequency of the connectors. The characteristic impedance for both single ended and differential mode signaling configurations using Time Domain Reflectometry simulations is also included in the report.
Touch Stone files including S2P files for single ended configuration and S4P files for differential mode signals are also included in the Signal Integrity Data download page for each CABLINE® series connector.
Table 1 and 2 below include the links to register and download the Signal Integrity Test reports and touchstone files for each CABLINE® Series connector. Once the product image or "SI Download" is clicked, you will be taken to a unique product page, the screen shot below the table for example shows the product page for CABLINE®-CA IIP PLUS connectors.
| Type | CABLINE®-CA IIP PLUS | CABLINE®-CAP | CABLINE®-UY | CABLINE®-VS II | CABLINE®-CA II | CABLINE®-CA II PLUS |
| Appearance (Reference Only) |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
| SI Data Download |
SI Data Download |
SI Data Download |
SI Data Download |
SI Data Download |
SI Data Download |
| Type | CABLINE®-UM | CABLINE®-CA | CABLINE®-VS | CABLINE®-CAL | CABLINE®-CA IIF PLUS | CABLINE®-CAL IIF |
| Appearance (Reference Only) |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
| SI Data Download |
SI Data Download |
SI Data Download |
SI Data Download |
SI Data Download |
SI Data Download |
| Type | CABLINE®-UA II | CABLINE®-UX II | CABLINE®-SS | CABLINE®-CX II With Cover | CABLINE®-CX II Without Cover |
| Appearance (Reference Only) |
![]() |
![]() |
![]() |
![]() |
![]() |
| SI Data Download |
SI Data Download |
SI Data Download |
SI Data Download |
SI Data Download |
For example, the product page for CABLINE®-CA IIP PLUS connectors, like all other CABLINE® series connectors, has a "Downloads" section as shown below. The Signal Integrity test reports and Touchstone files are posted in "Signal Integrity" tab of Downloads section.

Once the SI test reports or Touchstone files link is clicked, a new window pops open where you are required to register with email address before accessing the reports or Touchstone files.

Features and Benefits of I-PEX Micro-coaxial and Twinaxial Solutions
- 1. Micro-Coaxial Cable Harness
- 2. Twinaxial Cable Harness
- 3. Maximum Operating Frequency
- 4. Available Real Estate for Connector
- 5. EMI Shielding and Power Signals
- 6. Minimizing the Losses
- 7. Bending, Flexing and Twisting Requirements
- 8. Pin Out Assignments
- 9. Jacketing and Bundling Types
- 10. High-Speed Protocols
- 11. Harness Manufacturing Process
- 12. Signal Integrity Data
- 13. Signal Integrity Testing