MHF® 4L LK
下载
-
产品目录
-
2D图面
-
电缆组件
-
O.D. 1.37 mm
Standard orientation
-
-
3D STEP & IGES
-
Specs & Test Reports
-
PCB/FPC Data
-
Symbols(脚位图)和Footprints(封装图)
-
-
-
操作手册
连续冲击和震动的理想解决方案

MHF® 4L 公座自带锁扣结构

|
|
![]() |
||||
Product name |
MHF® 4L LK |
MHF® 4L |
MHF® 4L |
MHF® 4L |
|
Lock |
With Lock |
Without Lock |
Without Lock |
Without Lock |
|
Mating Height |
2.0 mm max. |
1.7 mm max. |
1.4 mm max. |
1.2 mm max. |
|
Coaxial O.D.
|
1.37 mm
|
● |
● |
|
|
1.13 mm
|
|
|
● |
|
|
0.95 mm
|
|
|
● |
|
|
0.81 mm
|
|
|
|
● |
|
0.64 mm
|
|
|
|
● |
|
Receptacle |
MHF® 4 receptacle (20449-001E-03), MHF® 4L receptacle (20579-001E) |
||||
| Product Type | Coaxial RF Connector
|
| Mated Height | 2.0 mm max.
|
| SMT Size | 2.0 x 2.0 mm
|
| Frequency Range | Up to 12 GHz (Up to 12 GHz for MHF®4L receptacle, Up to 9 GHz for MHF®4 receptacle) |
| Operating Temperature | |
| Cable Size (Micro-Coaxial) | AWG 30 O.D. 1.37 mm
|
| V.S.W.R (Plug) | DC to 3 GHz: 1.3 max.3 to 6 GHz: 1.4 max.6 to 9 GHz: 1.5 max.9 to 12 GHz: 1.6 max.
|
| Applicable Standards (Reference Only) | 5G sub6Wi-FiLTE / LTE-AdvancedLPWABluetoothGPS
|
| Full EMI Shielding (ZenShield®) | No
|
| Mechanical Lock | Yes
|
| VSWR (Harness only) | DC ~ 3 GHz : 1.3 max. 3 ~ 6 GHz : 1.4 max. 6 ~ 9 GHz : 1.5 max. 9 ~ 12 GHz : 1.6 max. |
推荐料号
若列表中查询不到您要查找的料号,请使用调查表询问。
*MHF 4L LK仅以MHF 4L LK 线束的形式销售
请指定线束组件规格(单端或双端、电缆尺寸、长度、颜色)。
MHF 4L LK RECOMMENDED PART NUMBERS
| Part Number Description | Part Number | Weight (mg) | Note |
| MHF 4L LK harness OD=1.37mm | Offered as harness only | - | *see note below |
| MHF 4L receptacle | 20579-001E | 8.48 |
*The MHF 4L LK is offered as our MHF 4L LK harness assembly only.
Please specify harness assembly specification (single-end or double-ended, cable size, length, color).
MHF 4L LK SAMPLE HARNESS FOR EVALUATION PART NUMBERS

| Part Number Description | Part Number | Weight (mg) |
| MHF 4L LK-4L LK harness OD=1.37mm L=100mm | 8-23-0110 | 740 |
| MHF 4L LK-4L LK harness OD=1.37mm L=200mm | 8-21-0044 | 630 |
| MHF 4L LK-4L LK harness OD=1.37mm L=300mm | 8-26-0054 | 1424.8 |
| MHF 4L LK-4L LK harness OD=1.37mm L=400mm | 8-26-0055 | 1854.8 |
| MHF 4L LK-4L LK harness OD=1.37mm L=500mm | 8-23-0111 | 700 |
MHF 4L LK SAMPLE HARNESS FOR EVALUATION PART NUMBERS

| Part Number Description | Part Number | Weight (mg) |
| MHF 4L LK-4L LK harness OD=1.37mm L=100mm 180 degree orientation | 8-25-0978 | 564 |
| MHF 4L LK-4L LK harness OD=1.37mm L=200mm 180 degree orientation | 8-25-0979 | 994 |
| MHF 4L LK-4L LK harness OD=1.37mm L=300mm 180 degree orientation | 8-25-0980 | 1424.8 |
| MHF 4L LK-4L LK harness OD=1.37mm L=400mm 180 degree orientation | 8-25-0981 | 1854.8 |
| MHF 4L LK-4L LK harness OD=1.37mm L=500mm 180 degree orientation | 8-25-0982 | 2284.8 |
其他料号
请注意:此列表可能包含了暂时还没有可用样品的产品和不再销售的型号。
如您有新的询价,请参考上述推荐的料号。
MHF 4L LK OTHER PART NUMBERS
| Part Number Description | Part Number | Weight (mg) | Note |
| MHF 4 receptacle | 20449-001E-03 | 4.54 | |
| MHF 4 receptacle thick plating type | 20449-001E | 4.54 |
MHF 4L LK ACCESSORIES PART NUMBERS
| Part Number Description | Part Number | Weight (mg) | Image |
| MHF 4/4L/4L LK SMA adapter for plug electrical-performance-check | 90449-001 | 2571.2 |
|
| MHF 4/4L/4L LK adapter for plug voltage-check | 90449-003-01 | 680 |
|
| MHF 4/4L/4L LK SMA adapter for receptacle electrical-performance-check | 90449-002 | 1685 |
|
| MHF 4/4L/4L LK SMA adapter for receptacle high-cycle | 90698-0001 | 7170 |
|
| MHF series SMA adapter for receptacle high-cycle narrow-pitch cable L=100mm | 90577-0100 | 4503.2 |
|
| MHF series SMA adapter for receptacle high-cycle narrow-pitch cable L=200mm | 90577-0200 | 5358.9 | |
| MHF series SMA adapter for receptacle high-cycle narrow-pitch cable L=350mm | 90577-0350 | 6571 | |
| MHF series SMA adapter for receptacle high-cycle narrow-pitch cable L=750mm | 90577-0750 | 9769.8 | |
| MHF 4/4L/4L LK SMA adapter for receptacle high-cycle probe | 90576-0001 | 1458.1 |
|
| MHF series SMA adapter for receptacle high-cycle detachable base | 90684-0001 | 15104.1 |
|
| MHF 4/4L/4L LK SMA adapter for receptacle high-cycle detachable probe | 90683-0001 | 1822.3 |
|
| MHF 4L insertion/extraction tweezer | 91166-0001 | 24580 |
|
| MHF 4L insertion/extraction tweezer narrow-pitch | 91493-0001 | 3560 |
|
SI Test Board with 2.92mm Adapter
| Part Number Description | Part Number | Weight (mg) | Image |
| SI Test Board for MHF 4L | 91602-001B-001 | 18066 |
Main Board
|
Locking/Unlocking and Insertion/Extraction tweezer to handle MHF® 4L LK
Hand Tools to operate locking/unlocking and insertion/extraction.
| Unlocking, Extraction tweezer | Narrow Pitch, Locking/Unlocking, Extraction tweezer |
Unlock the lock and remove it while holding the plug. |
The narrow-pitch design enables unlocking as well as insertion and removal, making it suitable for work in confined spaces. |
Adapters for plugs and receptacles
For plug inspection, Electrical Performance Check and Voltage/Continuity Check tools are provided.
Receptacle inspection tools, on the other hand, support Electrical performance check only.
The lineup includes various types to suit different applications, such as Standard series, High Cycle types with different durability ratings, and narrow-pitch types that enable operation on high-density PCB layouts.
| Standard series | High Cycle Series | ||
| Standard type | Narrow Pitch type | Detachable type | |
| Durability: 500 | Durability: 10,000 | Durability: 10,000 (Probe), 100 (Cable) | Durability: 10,000 (Probe), 200,000 (Base) |
Since the receptacle and the adapter are manually mated, the durability cycles are limited to 500. This type is best suited for inspection in small scale production environments, such as laboratories. |
The Standard type connects directly from the probe to the measuring instrument. |
The Narrow pitch type is designed with a tight pitch, allowing multiple probes to be aligned and measured simultaneously. |
The Detachable type allows the adapter and probe to be removed and replaced. The base adapter is compatible with all series. |
SI Test board for signal integrity performance measurement
Signal Integrity testing, measures and analyzes the extent to which high-speed signals maintain their integrity when transmitted through a connector.